BS6364 Leakage rate
Can someone tell me what the allowable leakage rate is for Spec BS6364 Cryo testing?
I may be mistaken...or simply out of date with my info, but, I believe
these are the same as per SPE 77/306 (I know they used to be the same).
Any one have more recent info ?
According to BS 6364 standard, para. A.3.1.4(d), the maximum allowable seat leakage is
100 mm3/s per mm of ND = 150 ml/min per in of DN,
for all valve types except check valve ones (that are allowed two times the above mentioned leakage).
Shell MESC SPE 77/306 specification in now withdrawn, as it has been superseded by Shell MESC SPE 77/200 in June 2007.