I have the following situation and was expecting maybe you can help me out.
I
have to pump a viscous fluid (1000cps) out of a 200L drum and up to a
mixing reactor. I have been discussing with my partners with regards to
the ability of a air operated diaphragm pump and a lobe PD pump to
extract the fluid in a condition of suction lift. What would be the
parameter I need to evaluate to know which pump will better pull (or
will not) the liquid from dry condition?
Some of my collegues tell me
I need to calculate NPSHa vs NPSHr. I think that calculation will tell
me about operating condition once the pump is filled with liquid; but
will not tell me about the ability to pull from dry condition. Am I
correct? (i.e. a centrifugal pump may have an NSPHr of 5ft; be installed
1ft above water and will never start pumping on its own; unless I fill
it with water...)
The manual of the Wilden pump I'm evaluating quotes
the MAX SUCTION LIFT (dry and wet; 11.5ft and 30.8ft respectively) What
is this? Does it mean that: geometric suction lift+friction loss+vapor
pressure < max suction lift?
The diaphragm pump is a positive displacement pump as is the rotary lobe pump. Positive displacement implies that there is a cavity that positivly expands and contracts to move the fluid through the pump. A centrifugal pump on the other hand does not have such cavities. Centrifugal pumps (and fans) rely on throwing the fluid out into a volute using a spinning disc (very crude description).
Back to
the OP; A diaphragm pump generates the suction by expanding a cavity
that is sealed using a non return valve. The pressure stroke is
generated in a similar fashion by compressing a cavity using a non
return valve. A rotary lobe pump on the other hand moves fluid around
the outside of the "gear mesh". "Suction" is generated by the opening
gear mesh and the "pressure" discharge is generated by the closing or
meshing gears. In the case of the diaphragm pump back flow is prevented
by a non return valve in the case of the lobe pump it is the mesh
clearances of the gears. Intuitivly the meshing gears will allow air
(vapour) to pass back through them and therefore limit the amount of "suction" it can
apply. Hence the diaphragm pump will be more likely to self prime.
In
relation to the fluid you are trying to lift or prime if the suction
pressure drops low enough it will boil and only vapour will be drawn to
the pump. Unless the pump can pump the boiled vapour away faster than it
is being generated the pump will not prime regardless of the pump type.
Regards