peristaltic pump stable inlet pressure
We're using a 1.5" peristaltic pump to empty a vertical container in a smooth and stable rate (around 30L/min).
What we noticed is a repeatable distortion in the flow rate caused by the peristaltic tube volume change due to the pump.
Roller engagement, causing momentary back flow. This phenomena is highly unwanted by us since it causes a pulsing flow pattern.
We're looking for a solution for that.
Use a multi-cavity (triplex) piston/plunger/diaphragm pump.
Along
the same principle as triplex and other multi-cavity pumps, try ganging
three or more peristaltics together, with the cam lobes timed 360/n/3
degrees apart (n = number of cam lobes). If you must stay with
peristaltics.